Dehumidifier - Pool Constant Temperature Dehumidification Heat Pump Unit
Negotiable | 1 Piece (MOQ) |
Min. Order:
1 Piece
Port:
Shanghai, China
Production Capacity:
1000piece/Year
Payment Terms:
L/C, T/T
Jiangyin Yihe Air Treatment Equipment Co., Ltd.
Jiangsu, China
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
YHE
Fan
With Fan
Dehumidification Capacity
20-30Kg/H
Control
Suitable Temperature
18-38 Degrees Celsius
Structure
Integral
Type
Transport Package
Wooden Box
Origin
China
HS Code
8407909090
Product Description
Operating principle of unit
The warm and wet air from the swimming pool space is inhaled by the return air section, and the controller automatically controls the electric air valve and the exhaust fan to discharge the appropriate indoor air and enter the appropriate outdoor fresh air. After the outdoor fresh air and the discharged indoor air exchange heat in the total heat exchanger, the fresh air enters the unit and mixes with the return air. The mixed air is cooled and dehumidified when passing through the evaporator. The damp heat and latent heat contained are absorbed by the refrigerant in the evaporator to gasify the refrigerant. Leave the evaporator of gaseous refrigerant entering the compressor, compressed into high pressure gaseous refrigerant, high-pressure gas refrigerant can according to different needs during summer and winter seasons, automatically controlled by electromagnetic valve into different condenser, such as: heat condenser (heating) air, heating the water condenser heating (water) or outdoor air cooling condenser (heat to outdoor). The dry and cold air after dehumidification is heated by the regenerative condensing coil and sent to the room.
In winter, the heat absorbed in the evaporator is sent to the regenerative condensing coil as required, and the gaseous refrigerant releases its recovered heat to heat the condensed dry air. Then, the treated air is heated through the auxiliary heating coil, and then fed into the swimming pool after raising the temperature. Or, according to demand, it is sent to the pool water heating condenser to heat the pool water in the constant temperature pool to achieve maximum heat recovery and utilization.
In summer, part of the heat absorbed by the evaporator enters the regenerative condenser and reheats the dried air. The other part enters the pool water to heat the condenser to heat the pool water according to the demand, in order to recover energy. Or enter the outdoor air cooling condenser to release excess heat to the outside.
Technical parameters
In winter, the heat absorbed in the evaporator is sent to the regenerative condensing coil as required, and the gaseous refrigerant releases its recovered heat to heat the condensed dry air. Then, the treated air is heated through the auxiliary heating coil, and then fed into the swimming pool after raising the temperature. Or, according to demand, it is sent to the pool water heating condenser to heat the pool water in the constant temperature pool to achieve maximum heat recovery and utilization.
In summer, part of the heat absorbed by the evaporator enters the regenerative condenser and reheats the dried air. The other part enters the pool water to heat the condenser to heat the pool water according to the demand, in order to recover energy. Or enter the outdoor air cooling condenser to release excess heat to the outside.
Technical parameters
Technical parameters of integrated pool thermostatic dehumidification heat pump | ||
Model | YCKA20W | |
Dehumidification | Kg/h | 20 |
Refrigerating capacity | kw | 33.9 |
Maximum heat production of air | kw | 42.9 |
Maximum heat production of pool water | kw | None |
The rated air flow | m³/h | 6000 |
The new air volume | m³/h | 0~3000 |
Exhaust air rate | m³/h | None |
Margin blast pressure | Pa | 300 |
Compressor | Type | Entire seal vortex type |
kw | 9.0 | |
Blower | Type | External rotor low noise centrifugal type |
kw | 1.5 | |
Refrigerating fluid | Type | R22 |
throttle type | External balance thermal expansion valve | |
Evaporator | Type | Copper tube sleeve coating aluminum sheet anticorrosion type |
Regenerative condenser | Type | Copper tube sleeve coating aluminum sheet anticorrosion type |
Diameter of condensate drain pipe | inch | 5/4 |
Outdoor fan | Type | Low noise axial flow of outer rotor |
kw | 0.8 | |
Power system | 380V/50HZ Air filter | |
The total power (kw) | 11.3Size | |
Air filter | Type | G4 |
Size | L(mm) | customization |
W(mm) | customization | |
H(mm) | customization | |
Weight(kg) | 340 |